VacPan II VCPW02-WM Dual Function Dustpan
Compatible with the following Brands & Models
(hover over each)
- Aggresor Please Call
- AirVac Please Call
- Astrovac Please Call
- Beam Please Call
- Black & Decker Please Call
- Broan Please Call
- Brute Please Call
- Budd Please Call
- Cana-Vac Please Call
- Centralux Please Call
- Cirrus Please Call
- CV International Please Call
- Dirt Devil Please Call
- DrainVac Please Call
- DuoVac Please Call
- DustCare Please Call
- Easy-Flo Please Call
- Electrolux Please Call
- Eureka Please Call
- Fasco Please Call
- Filtex Please Call
- Fridgidaire Please Call
- Hayden Please Call
- HoneyWell Please Call
- Hoover Please Call
- Imperium Please Call
- Kenmore Please Call
- MD Please Call
- Nadair Please Call
- NuTone Please Call
- Patton Please Call
- PowerStar Please Call
- Pullman-Holt Please Call
- PurVac Please Call
- Riccar Please Call
- Royal Please Call
- Sequoia Please Call
- Signature Please Call
- Simplicity Please Call
- Smart Please Call
- VacuFlow Please Call
- VacuMaid Please Call
- Valet Please Call
- Vent-A-Vac Please Call
- Walvac Please Call
- Whirlpool Please Call
- Zenex Please Call
Dual Function that Comments your Broom with the Power Of a Central Vacuum System
Ordering
VacPan II Dual Function Dustpan (White Only)
(Measurements are: 3.5" L x 1" W x 19" H)
The VacPan II is a must-have for any new or existing central vacuum system
The VACPAN II is a dual function central vacuum inlet valve system that will add a new dimension of convenience to your central vacuum system by complimenting your broom with the power of central vac. With the VacPan II, you can now brush dirt and debris toward the powerful suction to make your floor clean - instantly! Plus the VacPan II Dual Function Central Vac Inlet Valve System offers the added convenience of a standard hose inlet in one compact design. The original VacPan installs flush mounted into your baseboard or cabinet kickplate. VacPan II or Original VacPan Automatic Dustpan models provide unique benefits that allow you to choose the right model for each room. The Original VacPan & VacPan II can be installed on a new or existing central vacuum also in any combination!
VacPan II Installation
Plan the location of your VacPanII to be conveniently located for sweeping clean-ups. Also, consider ease of access to vacuum tube piping connections during installation.
Use Plastiflex part #SV8001 Standard Mounting Bracket for connecting VacPanII to vacuum tube piping.
New Construction Installation
-
VacPan II Wall Mount installs inside wall with a minimum stud width of 2-3/4"
-
VacPan II should be located against wall stud.
-
Once the VacPan II location is determined and prior to applying the wallboard, attach Plastiflex part #SV8001 Standard Mounting Bracket to the wall stud at the desired height up to 16" from sub-floor to center of vacuum tube piping.
-
Run vacuum tube piping and low voltage wire from the mainline to the VacPan II location and attach it to the mounting bracket.
-
Allow other trades to complete house construction like finished flowing and trim.
-
Remove baseboard trim from the area.
-
Attach low voltage wires to VacPanII terminal connections.
-
Slide VacPanII into mounting bracket and secure to a wall using two #10 X 1-1/2" screws provided. CAUTION: Do not over-tighten mounting screws as VacPanII operation can be affected.
-
Cut the VacPan II extension tube backplate to length to fit between the VacPan II valve and the finished floor.
-
Slide entrance ramp onto VacPan II extension tube back plate.
-
Drill two 1/8" holes through extension tube backplate and attach to the wall using two #8 3/4" screws and wall plugs provided.
-
Measure the distance from the finished floor to the top of the channel grooves on the VacPan II valve. Subtract 1/2" from the measurement to allow for sweep opening. Cut the extension tube channel to the determined length. Rough cut edges can be placed at the top and hidden under VacPan II top cover.
-
Snap extension tube channel overextension tube backplate & VacPan II valve.
-
Re-attach baseboard trim cutting it for a flush fit to your new VacPan II Wall Mount Dual Function Central Vacuum Inlet System.
Existing Wall Installations
-
VacPan II Wall Mount can be installed inside any wall with a minimum stud width of 2-3/4" or cabinet end gable. Once the VacPan II location is determined, remove any baseboard trim from the area.
-
Cut a 4-1/4" x 2-3/8" hole in the wallboard, at the desired height up to 16" from the floor to the center of vacuum tubes piping, to accept Plastiflex part #SV8001 Standard Mounting Bracket. Break off the "new construction flange" of the mounting bracket. If using other mounting brackets, cut an appropriately sized hole so that the center of vacuum tube piping is up to 16" above the floor.
-
Run vacuum tube piping and low voltage wire from the mainline to the VacPan II location and attach it to the mounting bracket.
-
Attach low voltage wires to VacPan II terminal connections. Slide VacPan II into mounting bracket and secure to a wall using two #10 x 1-1/2" screws provided. CAUTION: Do not over-tighten mounting screws as VacPan II operation can be affected.
-
Cut the VacPan II extension tube backplate to length to fit between the VacPan II valve and the finished floor.
-
Drill two 1/8" holes through extension tube backplate and attach to the wall using two #8 x 3/4" screws and wall plugs provided.
-
Measure the distance from the finished floor to the top of the channel grooves on the VacPan II valve. Subtract 1/2" from the measurement to allow for sweep opening. Cut the extension tube channel to the determined length. Rough cut edges can be placed at the top and hidden under VacPan II top cover.
-
Snap extension tube channel overextension tube backplate and VacPan II valve.
-
Re-attach baseboard trim cutting it for a flush fit to your new VacPan II Wall Mount - Dual Function Central vacuum Inlet System.
VacPanII Operating Instructions
-
VacPan II Wall Mount - Dual Function Central Vacuum Inlet System can be used as both a sweep inlet and a standard hose inlet.
-
For Sweep Inlet operation, slide the top cover-up, automatically switching on the central vacuum system. Sweet material into the opening. When complete, slide the top cover down, automatically shutting off the central vacuum system.
-
For Standard Hose Inlet operation, ensure top cover is in a fully lowered position. Grasp side finger grips in the top cover and flip-top cover-up. The top cover will lockout of the way. Lift sprung flapper door open and insert the central vacuum hose. Use your central vacuum hose as you would with any other standard inlet valve.
Inlet Types and Installation Diagrams
Auto-On Inlet | Yes |
---|---|
General Construction Material | ABS Plastic |
Color | White |
Product Width (Inches) | 1 |
Product Height (Inches) | 19 |
Product Length (Inches) | 3.5 |
Qty Per Pack | 1 |
Read about the Dual Function VacPan II Automatic Dustpan VCPW02-WM
VacPan II Dual Function Dustpan (White Only)
(Measurements are: 3.5" L x 1" W x 19" H)
The VacPan II is a must-have for any new or existing central vacuum system
The VACPAN II is a dual function central vacuum inlet valve system that will add a new dimension of convenience to your central vacuum system by complimenting your broom with the power of central vac. With the VacPan II, you can now brush dirt and debris toward the powerful suction to make your floor clean - instantly! Plus the VacPan II Dual Function Central Vac Inlet Valve System offers the added convenience of a standard hose inlet in one compact design. The original VacPan installs flush mounted into your baseboard or cabinet kickplate. VacPan II or Original VacPan Automatic Dustpan models provide unique benefits that allow you to choose the right model for each room. The Original VacPan & VacPan II can be installed on a new or existing central vacuum also in any combination!
VacPan II Installation
Plan the location of your VacPanII to be conveniently located for sweeping clean-ups. Also, consider ease of access to vacuum tube piping connections during installation.
Use Plastiflex part #SV8001 Standard Mounting Bracket for connecting VacPanII to vacuum tube piping.
New Construction Installation
-
VacPan II Wall Mount installs inside wall with a minimum stud width of 2-3/4"
-
VacPan II should be located against wall stud.
-
Once the VacPan II location is determined and prior to applying the wallboard, attach Plastiflex part #SV8001 Standard Mounting Bracket to the wall stud at the desired height up to 16" from sub-floor to center of vacuum tube piping.
-
Run vacuum tube piping and low voltage wire from the mainline to the VacPan II location and attach it to the mounting bracket.
-
Allow other trades to complete house construction like finished flowing and trim.
-
Remove baseboard trim from the area.
-
Attach low voltage wires to VacPanII terminal connections.
-
Slide VacPanII into mounting bracket and secure to a wall using two #10 X 1-1/2" screws provided. CAUTION: Do not over-tighten mounting screws as VacPanII operation can be affected.
-
Cut the VacPan II extension tube backplate to length to fit between the VacPan II valve and the finished floor.
-
Slide entrance ramp onto VacPan II extension tube back plate.
-
Drill two 1/8" holes through extension tube backplate and attach to the wall using two #8 3/4" screws and wall plugs provided.
-
Measure the distance from the finished floor to the top of the channel grooves on the VacPan II valve. Subtract 1/2" from the measurement to allow for sweep opening. Cut the extension tube channel to the determined length. Rough cut edges can be placed at the top and hidden under VacPan II top cover.
-
Snap extension tube channel overextension tube backplate & VacPan II valve.
-
Re-attach baseboard trim cutting it for a flush fit to your new VacPan II Wall Mount Dual Function Central Vacuum Inlet System.
Existing Wall Installations
-
VacPan II Wall Mount can be installed inside any wall with a minimum stud width of 2-3/4" or cabinet end gable. Once the VacPan II location is determined, remove any baseboard trim from the area.
-
Cut a 4-1/4" x 2-3/8" hole in the wallboard, at the desired height up to 16" from the floor to the center of vacuum tubes piping, to accept Plastiflex part #SV8001 Standard Mounting Bracket. Break off the "new construction flange" of the mounting bracket. If using other mounting brackets, cut an appropriately sized hole so that the center of vacuum tube piping is up to 16" above the floor.
-
Run vacuum tube piping and low voltage wire from the mainline to the VacPan II location and attach it to the mounting bracket.
-
Attach low voltage wires to VacPan II terminal connections. Slide VacPan II into mounting bracket and secure to a wall using two #10 x 1-1/2" screws provided. CAUTION: Do not over-tighten mounting screws as VacPan II operation can be affected.
-
Cut the VacPan II extension tube backplate to length to fit between the VacPan II valve and the finished floor.
-
Drill two 1/8" holes through extension tube backplate and attach to the wall using two #8 x 3/4" screws and wall plugs provided.
-
Measure the distance from the finished floor to the top of the channel grooves on the VacPan II valve. Subtract 1/2" from the measurement to allow for sweep opening. Cut the extension tube channel to the determined length. Rough cut edges can be placed at the top and hidden under VacPan II top cover.
-
Snap extension tube channel overextension tube backplate and VacPan II valve.
-
Re-attach baseboard trim cutting it for a flush fit to your new VacPan II Wall Mount - Dual Function Central vacuum Inlet System.
VacPanII Operating Instructions
-
VacPan II Wall Mount - Dual Function Central Vacuum Inlet System can be used as both a sweep inlet and a standard hose inlet.
-
For Sweep Inlet operation, slide the top cover-up, automatically switching on the central vacuum system. Sweet material into the opening. When complete, slide the top cover down, automatically shutting off the central vacuum system.
-
For Standard Hose Inlet operation, ensure top cover is in a fully lowered position. Grasp side finger grips in the top cover and flip-top cover-up. The top cover will lockout of the way. Lift sprung flapper door open and insert the central vacuum hose. Use your central vacuum hose as you would with any other standard inlet valve.
Inlet Types and Installation Diagrams
Log In
Create New Account